Powercom KIN-3000AP, 3000VA, 4+3 Outlets

340129 Powercom KIN-3000AP

$434.00Price
  • AC INPUT AC Input Capacity on Battery : 3000VA AC Input Voltage : (+/-) 25% at line input AC Input Frequency : 50 or 60 Hz+/-10% (auto sensing) AC OUTPUT AC Output Voltage : Simulated sine ware at 115V +/-5% AC Output Frequency : 50 or 60 Hz +/- 0.5% AC Output Voltage Regulation : AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal. AVR decrease output voltage 13% below input voltage if +9% to +25% of nominal AC Output Transfer : 2/4 milliseconds, including detection time PROTECTION Protection Spike : 320 Joules, 2ms Protection EMI/RFI : 10dB at 0.15 MHz, 50 dB at 30 MHz Protection Overload : UPS automatic shutdown if overload exceeds 110% nominal at 60 sec and 130% at 3 sec Protection Unit Fuse for overload & short circuit protection Protection 10 BaseT Network (UTP, RJ-45) compatible jacks Protection Short Protection : UPS output cut off immediately or input fuse protection BATTERY Battery Type : Sealed, Maintenance-free lead acid, with 3 - 6 years typical lifetime Battery Typical : 4 hours (to 90% of full capacity) Battery Protection : Automatic self-test & discharge protection, replace battery indicator Battery Run Time : 140 - 160 minutes PHYSICAL Weight : 32Kg (71lbs) Shipping Weight: 34Kg (75lbs) Dimension : 298x685x360mm (11.7x27x14.2") ALARM Alarm Battery Backup : Slow beeping sound (about 0.47 Hz) Alarm Battery Low : Rapid beeping sound (about 1.82Hz) Alarm Overload : Continue beeping sound INTERFACE Interface RS-232 : Bi-directional communication port ENVIRONMENT Environment Ambient 3,500 meters max. elevation, 0-95% humidity non-condensing, 0-40 deg c Environment Audible <40dBA (1 meter from surface)